Victron Orion-Tr 24/48-6A Isolated DC-DC Converter 280W
Free returns on all eligible orders
You have 30 days to request a return. All sale items are final sale.
Shipping information
Use this text to share information about your product.
Returns & warranty
Use this text to share information about your product.
Description
Provide a stable DC output voltage using the easy to install Orion DC-DC Inverter from Victron Energy. This model is designed for applications requiring a reliable power source with galvanic isolation.
The Orion-Tr 24/48-6A converter features a continuous output power of 280W at 40°C and can handle up to 320W at 25°C. It operates within an input voltage range of 16 to 35V and provides an output voltage of 48.2V with a tolerance of 200 mVrms.
With a compact design, the converter measures 186 mm in width, 130 mm in height, and 70 mm in depth, making it suitable for various installations. It is also equipped with protections against short circuits and overheating, ensuring safety during operation.
Key Features
- Continuous output power: 280W at 40°C, 320W at 25°C
- Input voltage range: 16-35V
- Output voltage: 48.2V with 200 mVrms tolerance
- Compact dimensions: 186x130x70 mm
- IP43 protection category for durability
- Galvanic isolation for enhanced safety
Specifications
| Brand | Victron |
| EAN | 8719076035275 |
| Type | Power Product |
| Sub-Type | other |
| Custom Bundle | No |
| Remote On Off Terminal Connection | Screw terminal two pole |
| DC connection terminal type | Screw terminals 16 mm² (6 AWG) |
| Weight | 1.3 kg |
| Item Depth | 70 mm |
| Item Width | 186 mm |
| Protection Category | IP43 |
| Item Height | 130 mm |
| Colour | Blue (RAL 5012) |
| Automotive directive | ECE R10-5 |
| Emission | EN 55014-1,EN-IEC 61000-6-3 |
| Immunity | EN 55014-2,EN-IEC 61000-6-1, EN-IEC 61000-6-2 |
| Safety | EN 60950 |
| Output voltage | 48.2 V |
| Output Voltage Noise | 2 mVrms |
| Output voltage range | [40, 60] V |
| Output Voltage Tolerance | 200 mVrms |
| Parallelable | True |
| Protections | Short-circuit proof,Over temperature |
| Remote on/off terminal | True |
| Standby current Consumption | 0.2 mA |
| Under voltage restart | 15 V |
| Under voltage shutdown | 14 V |
| Operating temperature rang | [-20, 55] °C |
| Continuous output power at 25°C | 320 W |
| Continuous output power at 40°C | 280 W |
| Continuous output current rating up to 40°C | 6 A |
| Galvanic isolation | True |
| Input voltage range | [16, 35] V |
| Isolation | 200 VDC |
| Maximum efficiency | 89 |
| Maximum humidity (non-condensing) | 95 % |
| Maximum output current | 8 |
| Maximum continuous short-circuit current | 25 A |
| No-load current consumption | 120 mA |
| Manufacturer Part Number (MPN) | ORI244828110 |